Home > Sound Control > Enkasonic® HP

Enkasonic® HP Fire Ratings/Detail Drawings Maxxon Green Mark

Acousti-Mat II
Click here to download Maxxon's BIM files

AEnkasonic® HP Detail Drawings

Drawing Type Assembly / Description
3D Drawings Enkasonic HP over 2x10 Wood Joist
Enkasonic HP over Concrete
Enkasonic HP over I-Joist
Enkasonic HP over Parallel Chord Truss
Enkasonic HP over Precast
Enkasonic HP over Steel Joist with Steel Deck
Enkasonic HP over Steel Joist with Plywood Deck
Isolation Drawings Typical Installation

 

Fire Rating Information

Assembly HR Description UL# CAD Drawings
Parallel Chord Truss 1 HR w/ Insulation & Resilient Channel L528, L546, L558, L576, M503, M508 dwg DWG File pdf PDF File
1 HR w/ Resilient Channel
(optional insulation)
L528, L534, L562, L563, L574, L579, L585, L592
1 HR w/ Suspended Ceiling L529
1 HR Drywall Screwed Direct L542
1 HR w/ Kinetics Ceiling Hangers L581, L583, ICC ESR #3207
2 HR w/ 3+ Layers of Drywall L556, L577, M500, M510

 

Assembly HR Description UL# CAD Drawings
I-Joist 1 HR w/ Insulation & Resilient Channel L571, L589, M 502, Warnock Hersey #J20050694 dwg DWG File pdf PDF File
1 HR w/ Resilient Channel
L518, L547
1 HR w/ Simpson Strong Tie Clips L530
1 HR w/ 2 Layers of Drywall L570, L590, M506
1.5 HR Drywall Screwed Direct ICC ESR #1153
2 HR w/ 3+ Layers of Drywall L538, L556

 

Assembly HR Description UL# CAD Drawings
2x10 Wood Frame 0.5 HR Drywall Screwed Direct L509 dwg DWG File pdf PDF File
0.75 HR Drywall Screwed Direct
L506, M504
0.75 HR w/ Insulation & Resilient Channel L520
1 HR Drywall Screwed Direct L501, L503, L507, L512, L519, L522, L523, L537, L557, L588, M517
1 HR w/ Furring Channel L515
1 HR w/ Resilient Channel L514, L516, L517, L523, L533, L535, L545, L593
1 HR w/ Insulation & Resilient Channel L502, L513, L516, L533, L545, L569, L593, M514, M518, M519
1 HR w/ Kinetics Ceiling Hangers L581, L583
1 HR Independent Rafter Ceiling L539, L540
1 HR w/ Insulation & Resilient Channel and Type "X" Gypsum Board ICC ESR #2540
1 HR w/ Suspended Ceiling Tiles L006, L201, L202, L206, L209, L210, L212
1 HR Suspended Drywall L525, L526
1 HR w/ Sound Board L504
1.5 HR w/ 2 Layers of Drywall L510
2 HR w/ 2 Layers of Drywall L505, L511, L536, L541
2 HR w/ 4 Layers of Drywall L556
2 HR Independent Rafter Ceiling L211

 

Assembly HR Description UL# CAD Drawings
Light Gauge Steel Joist Construction with Corrugated Steel Deck 1, 1.5, 2, 3 HR Vulcraft Steel Deck G561 dwg Not Avail. pdf PDF File
1, 2 HR Clark/Deitrich Joist
G551, G553, G560*
1, 2 HR Gateway Joist G566
2 HR Marino\WARE Joist G563
2 HR CEMCO Joist G574

 

Assembly HR Description UL# CAD Drawings
Light Gauge Steel Joist Construction with Plywood or OSB Subfloor 1 HR Drywall Screwed Direct L524 dwg DWG File pdf PDF File
1 HR Independent Rafter Ceiling
L543
1 HR w/ Viroc Subfloor L564
1 HR w/ Insulation & Resilient Channel L565, L567, M505, M513
1 HR w/ 23/32" Wood Panel, Insulation & Resilient Channel L560
1.5 HR w/ Resilient Channel and 2 Layers of Drywall L527
2 HR w/ 4 Layers of Drywall L556

 

Assembly HR Description UL# UL/ULC CAD Drawings
TotalJoist by iSPAN with Steel Deck 1 HR Plywood, OSB or Steel Deck M511 UL dwg Not Avail. pdf PDF File
1 HR Plywood, OSB
M515 UL
1 HR Plywood, OSB or Steel Deck M520 ULC
1 HR Steel Deck M521 ULC
1.5, 2 HR Steel Deck I530 ULC
2 HR Steel Deck G587 UL

 

Assembly HR Description UL# UL/ULC CAD Drawings
TotalJoist by iSPAN with Plywood or OSB 1 HR Plywood, OSB or Steel Deck M511 UL dwg Not Avail. pdf PDF File
1 HR Plywood, OSB
M515 UL
1 HR Plywood, OSB or Steel Deck M520 ULC

 

Assembly HR Description UL# CAD Drawings
Light Gauge Steel Web Truss 1 HR w/ Insulation & Resilient Channel L549, L551, L552, L560 dwg Not Avail. pdf Not Avail.
1 HR Batt Insulation Optional & Resilient Channel
M507

 

Assembly HR Description UL# CAD Drawings
TJL Truss 1 HR w/ Resilient Channel L518 dwg DWG File pdf PDF File
2 HR w/ 3 Layers of Drywall
L538
1, 2 HR Several Options ICC-ESR #1774

 

Assembly HR UL# CAD Drawings
Precast Concrete 2 HR J917, J927 dwg DWG File pdf PDF File
1.5, 2, 3, 4 HR J991, J994
2, 3 HR J920, J931, J957, J958
2, 3, 4 HR J919, J924

 

Assembly HR UL# CAD Drawings
Double T Concrete 2, 3, 4 HR J804, J805 dwg Not Avail. pdf PDF File

 

Assembly HR UL# CAD Drawings
Bar Joist Framing 1 HR Warnock Hersey Test #WH1-694-029 dwg DWG File pdf PDF File

 

Assembly HR UL# CAD Drawings
Hambro Systems 1, 1.5, 2 HR G524 dwg Not Avail. pdf PDF File

 

Assembly HR UL# CAD Drawings
Spacejoist TE 1 HR TSC/FCA 60-01 dwg DWG File pdf PDF File

 

Underlayment Depth
Sound Mat Underlayment Depth Underlayment Depth with Reinforcement
Acousti-Mat I 3/4" (19 mm) n/a
Acousti-Mat II 1" (25mm) 3/4" (19mm)
Acousti-Mat II HP 1" (25mm) n/a
Enkasonic 1 1/2" (38mm) 1" (25mm)
Enkasonic HP 1 1/2" (38mm) 1" (25mm)
Acousti-Mat 3
1 1/2" (38mm) plus Maxxon CSM or wire mesh
1 1/2" (38mm)
Acousti-Mat 3 HP
1 1/2" (38mm) plus Reinforcement
1 1/2" (38mm)
Back to Top