Home > Moisture Vapor Treatments > Aquafin® SG4

Aquafin® Vaportight Coat SG4 Data Sheet



Manufacturer:

AQUAFIN® Inc.
www.aquafin.net
info@aquafin.net
Phone: 1-866-278-2346

Distributor:

Maxxon® Corporation
920 Hamel Road
P.O. Box 253
Hamel, MN 55340
Phone: 1-800-356-7887 or (763) 478-9600
Fax: (763) 478-2431

Product Description:

Aquafin® Vaportight Coat SG4 is a rapid setting 2-component, moisture tolerant, low viscosity, solvent free, chemically enhanced epoxy-based product which reduces the passage of water vapor and moisture through slabs on, below and above grade as well as split slabs, thus eliminating delamination of adhesives, floor coverings and coatings.

Product Advantages:

  • One coat system - No sand broadcasting
  • Low viscosity, solvent free, no VOC's
  • ASTM E 96 perm rating equal to or less than 0.10
  • Can be applied to damp & green concrete (min. 5 days old)
  • Great for indoor applications: low odor and non-flammable

Technical Data:

  Vaportight Coat SG2 Vaportight Coat SG3 Vaportight Coat SG4
Material 2-component white epoxy 2-component clear epoxy 2-component clear epoxy
Min. Requirements over New Concrete Concrete must be a minimum of 5 days old or have reached a minimum of 2500 psi (17 MPa)
Workability Time
@ 73° F (23° C)
approx. 60 minutes approx. 35 minutes approx. 15 minutes
Sand Broadcast Required Yes No

No

Open to foot traffic
@ 73° F (23° C)
after 12 hours after 12 hours after 3.5 hours
Adhesion to Concrete
(ASTM D7234)
>480 psi >480 psi

>580 psi

VOC 47 g/L 0 g/L 0 g/L
Recommended application thickness for 100% RH (per ASTM F 2170) and yield per kit 21 mils
Yield: 160 sq. ft.
16 mils
Yield: 240 sq. ft.
16 mils
Yield: 240 sq. ft.
Option to Adjust Yield No Yes Yes
Dry time before pour minimum 24 hours minimum 12 hours
maximum 5 days

INDOOR
minimum 3.5 hours
maximum 5 days

OUTDOOR
minimum 3.5 hours
maximum 24 hours

Typical Applications
  • Indoor and Outdoor
  • New and existing Concrete slabs: on grade above grade, below grade and split slabs
  • Office Buildings
  • Medical Facilities
  • Industrial/Retail Facilities
  • Educational Facilities
  • Oil and other chemically contaminated slabs
  • Food processing plants
  • Secondary containment slabs, etc.
  • Old cementitious underlayment (no gypsum) and ceramic tiles with missing or damaged under-slab vapor barriers
  • Supermarkets
  • Food processing plants
  • Airplane hangars
  • For capillary infiltration of oil or other chemicals from the ground or to treat oil-contaminated slabs or radon infiltration
  • Old cementitious underlayment (no gypsum) and ceramic tiles with missing or damaged under-slab vapor barriers
  • Supermarkets
  • Food processing plants
  • Airplane hangars
  • For capillary infiltration of oil or other chemicals from the ground or to treat oil-contaminated slabs or radon infiltration


All data are average values obtained under laboratory conditions. In practical use temperature, humidity and absorbence of the substrate may influence the above given values.

Code Listings:
  • ESR-2540
  • ESR-1153
  • ESR-1141
  • ESR-1774
  • HUD951i
  • City of Los Angeles