| Floor System |
Topping |
Insulation |
Ceiling Susp. on Chan. |
Ceiling Drywall |
Floor Covering |
Rating |
Test Number |
| 8" Concrete (203 mm) |
1/2" Level-Right
WearTop
|
No
|
No |
No |
None |
F-IIC 55 |
F07-656 |
| Steel joists |
1 9/16" Maxxon |
Batt |
Yes |
5/8" (16 mm) |
Ceramic Tile |
IIC 51
STC 57 |
NGC 7008010
NGC 7008019 |
12" TJIĀ® Joist
w/ 3/4" (19mm)
plywood subfloor |
3/4" Maxxon
3/4" Maxxon
3/4" Maxxon |
Batt
Batt
Batt |
Yes
Yes
Yes |
2 layers; 5/8" (16 mm)
2 layers; 5/8" (16 mm)
2 layers; 5/8" (16 mm) |
None
Ceramic Tile
Vinyl |
A-STC 57
F-IIC 49
F-IIC 47 |
35-09-3
35-09-1a
35-09-1c |
Parallel Chord Truss
2" x 4" (50 x 102 mm)
w/ 3/4" (19 mm) OSB subfloor |
3/4" Maxxon
3/4" Maxxon
3/4" Maxxon
3/4" Maxxon
3/4" Maxxon |
Batt
Batt
Batt
Batt
Batt |
Yes
Yes
Yes
Yes
Yes |
5/8" (16 mm)
5/8" (16 mm)
5/8" (16 mm)
5/8" (16 mm)
5/8" (16 mm) |
Vinyl Plank
Ceramic Tile
Vinyl
Laminate Wood
None |
F-IIC 59
F-IIC 57
F-IIC 54
F-IIC 58
F-STC 56 |
02462-1
02462-2
02462-3
02462-5
02462-9 |
No Acousti-Mat LPR (control)
|
3/4" Maxxon
3/4" Maxxon |
Batt
Batt |
Yes
Yes
|
5/8" (16 mm)
5/8" (16 mm)
|
Ceramic Tile
Vinyl
|
F-IIC 47
F-IIC 47
|
02462-6
02462-7
|
Laboratory Sound Test: Delta IIC 19 per ASTM E 2179-03
F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests above, plus additional tests are available upon request.
Acousti-Mat LP is but one component of an effective sound control system.
No sound control system is better than its weakest component.
Care must be taken in the installation of components of construction to assure
the ultimate designed acoustical performance.