| 1 Contact Maxxon for anti-fracture properties |
2 Minimum Gypsum Underlayment depth: 3/4" |
3 Minimum Level-Right WearTop depth: 3/8" |
Application Detail Photos
Sound Test Results
| Topping |
Insulation |
Resilient Channel |
Ceiling Drywall |
Floor Covering |
Rating |
Test Number |
| Steel Frame with 9/16" corrugated, 9 1/4" Steel Joists, Acousti-Mat LPR |
| 1 9/16" (39.7 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
Ceramic Tile** |
IIC 51 |
NGC 7008010 |
| 1 9/16" (39.7 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
Ceramic Tile** |
STC 57 |
NGC 7008019 |
| Wood Frame with 3/4" subfloor, 18" deep parallel chord trusses, Acousti-Mat LP |
| 3/4" (19 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
Ceramic Tile** |
IIC 50 |
NGC 7007131 |
| 3/4" (19 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
Laminate Wood** |
IIC 53 |
NGC 7007132 |
| 3/4" (19 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
Ceramic Tile** |
STC 56 |
NGC 5007071 |
| Wood Frame with 3/4" subfloor, 18" deep parallel chord trusses, Acousti-Mat LP |
| 1 1/4" (32 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
DuraCeramic Tile** |
F-IIC 51 |
90744-15 |
| 1 1/4" (32 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
Laminate Wood** |
F-IIC 51 |
90744-17 |
| 1 1/4" (32 mm) Maxxon* |
Yes |
Yes |
5/8" (16 mm) |
None |
A-STC 53 |
90744-18 |
* Approved Maxxon Underlayment ** Floor good installed directly to the surface of Acousti-Mat LP or Acousti-Mat LPR
F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests above, plus additional tests are available upon request.
Acousti-Mat LP and LPR are but one component of an effective sound control system.
No sound control system is better than its weakest component.
Care must be taken in the installation of components of construction to assure
the ultimate designed acoustical performance.