| Floor System |
Topping |
Insulation |
Ceiling Susp.
on Chan. |
Ceiling Drywall |
Floor Covering |
Rating |
Test Number |
| 6" Concrete (152 mm) |
Thinset with Tile
Thinset with Tile |
No
No |
No
No |
No
No |
Quarry Tile
Quarry Tile |
STC 54
Delta IIC 19 |
NGC 5006017
NGC 7006023 |
| 8" Concrete (203 mm) |
1/2" Maxxon
1/2" Maxxon |
No
No |
Yes
Yes |
5/8" (16 mm)
5/8" (16 mm) |
None
Wood |
57 F-IIC
60 F-IIC |
0677973
0677973 |
Bare Concrete,
No AM LP (control) |
None |
No |
Yes |
5/8" (16 mm) |
None |
42 F-IIC,
62 F-STC |
0677973 |
| 8" Concrete (203 mm) |
1/4" Level-Right
WearTop |
No |
No |
No |
None |
59 F-IIC |
72550 |
Bare Concrete,
No AM LP (control) |
None |
No |
No |
No |
None |
37 F-IIC |
72550 |
| 8" Concrete (203 mm) |
None |
No |
No |
No |
Laminate Wood |
63 F-IIC |
F07-660 |
Bare Concrete,
No AM LP (control) |
None
None |
No
No |
No
No |
No
No |
None
None |
34 F-IIC
61 A-STC |
F07-568
F07-567 |
| 8" Concrete (203 mm) |
None
None |
No
No |
No
No |
No
No |
Ceramic Tile
Laminate Wood |
52 F-IIC
57 F-IIC |
1071202-3
1071202-2 |
Bare Concrete,
No AM LP (control) |
None |
No |
No |
No |
None |
35 F-IIC |
1071202-1 |
2" x 4" Parallel Chord Truss
with 3/4" OSB |
3/4" Maxxon
3/4" Maxxon
3/4" Maxxon |
Yes
Yes
Yes |
Yes
Yes
Yes |
5/8" (16 mm)
5/8" (16 mm)
5/8" (16 mm) |
Ceramic Tile
Ceramic Tile
Laminate Wood |
50 IIC
56 STC
53 IIC |
NGC 7007131
NGC 5007071
NGC 7007132 |
Laboratory Sound Test: Delta IIC 19 per ASTM E 2179-03
F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests above, plus additional tests are available upon request.
Acousti-Mat LP is but one component of an effective sound control system.
No sound control system is better than its weakest component.
Care must be taken in the installation of components of construction to assure
the ultimate designed acoustical performance.