| Floor System |
Topping |
Insulation |
Ceiling Susp.
on Chan. |
Ceiling Drywall |
Floor Covering |
Rating |
Test Number |
| 8" Concrete (203 mm) |
1/2" (12 mm) Maxxon
1/2" (12 mm) Maxxon |
No
No |
Yes
Yes |
5/8" (16 mm)
5/8" (16 mm) |
None
Wood |
57 F-IIC
60 F-IIC |
0677973
0677973 |
Bare Concrete,
No AM LP (control) |
None |
No |
Yes |
5/8" (16 mm) |
None |
42 F-IIC,
62 F-STC |
0677973 |
| 8" Concrete (203 mm) |
1/4" (6 mm) Level-Right
WearTop |
No |
No |
No |
None |
59 F-IIC |
72550 |
Bare Concrete,
No AM LP (control) |
None |
No |
No |
No |
None |
37 F-IIC |
72550 |
| 8" Concrete (203 mm) |
None
None |
No
No |
No
No |
No
No |
Ceramic Tile
Laminate Wood |
52 F-IIC
57 F-IIC |
1071202-3
1071202-2 |
Bare Concrete,
No AM LP (control) |
None |
No |
No |
No |
None |
35 F-IIC |
1071202-1 |
Laboratory Sound Test: Delta IIC 19 per ASTM E 2179-03
F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests above, plus additional tests are available upon request.
Acousti-Mat LP is but one component of an effective sound control system.
No sound control system is better than its weakest component.
Care must be taken in the installation of components of construction to assure
the ultimate designed acoustical performance.