| Floor System |
Underlayment |
Insulation |
Ceiling Susp. on Chan. |
Ceiling Drywall |
Floor Coverings |
Rating |
Test Numbers |
Acousti-Mat 3 over Open Beam
|
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
|
None
None
None
|
No
No
No
|
No
No
No
|
Vinyl
Wood Floating Floor
None
|
46 F-IIC
52 F-IIC
47 F-STC
|
02 31573.3
02 31573.4
02 31573.6
|
| Bare Floor over Open Beam (control) |
None |
None |
No |
No |
None |
33 F-IIC
30 F-STC |
02 31573.5
02 31573.7 |
Acousti-Mat 3 over
8" Cast-in-Place Concrete (203 mm)
|
2" (51 mm) Maxxon*
2" (51 mm) Concrete
|
None
None
|
No
No
|
No
No
|
None
None
|
65 F-IIC
61 F-IIC
|
03 56381.6
03 56381.5
|
Bare Concrete,
no Acousti-Mat (control) |
None |
None |
No |
No |
None |
36 F-IIC |
03 56381.1 |
Steel Joist
12" Deep (305 mm)
w/ 3/4" (19 mm) T&G plywood subfloor |
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon* |
Batt
Batt
Batt |
Yes
Yes
Yes |
5/8" (16 mm)
5/8" (16 mm)
5/8" (16 mm) |
Ceramic
Vinyl
Wood |
57 F-IIC
57 F-IIC
58 F-IIC
|
04-22-1
04-22-2
04-22-3 |
TJI® Joist w/3/4" (19mm)
T&G OSB Subfloor |
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon* |
Batt
Batt |
Yes
Yes |
2 layers 5/8"
(2 x 16 mm)
2 layers 5/8" (2 x 16 mm) |
Ceramic
Ceramic |
58 F-IIC
59 F-STC |
48-06-03
48-06-04 |
*Approved Maxxon Underlayment
F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E989.
F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413.
Actual tests are available upon request.
Maxxon Underlayments and Acousti-Mat II are but two components of an effective sound control system.
No sound control system is better than its weakest component.
Care must be taken in the installation of components of construction to assure