Spotlight on Dura-Cap®
Market Common with 34,000 sq. ft. of Dura-Cap® topping corrugated steel deck.

Acousti-Mat® 3 Fire Ratings/Detail Drawings Maxxon Green Mark

Click here to download Maxxon's BIM files
  CAD Drawings
Detail Drawings Description DWG File PDF File

fire Bar Joist Framing

1 Hour - Warnock Hersey Test #WH1-694-029

dwg DWG File

pdf PDF File

fire Hambro Systems

1, 1.5, & 2 Hour - UL Design No. G524

dwg Not Avail.

fire Light Gauge Steel

1 Hour - U.L. Design No. L524,
furring channels and 2 layers 5/8" Gypsum Board - L573
Metal joist, Viroc subfloor, batt insulation with
resilient channel and 1 layer 5/8" Type C Gypsum
Board - L564
iSpan Light Gauge Steel Joist w/batt insulation, resilient channel, 5/8" gypsum board - L575, L594
w/batt insulation, resilient channel, & 2 layers 5/8" gypsum board - M505
1.5 Hour - w/resilient channel & 2 layers, 5/8" Gypsum Board - L527
NUJOIST Steel Joist, 24" o.c. with Wood Subfloor, Resilient Channel, 2 layers 5/8" Gypsum Board- L599

dwg DWG File

pdf PDF File

fire Parallel Chord Truss

1 Hour - U.L. Design Nos. L528, L529, L534
w/batt insulation - L546, L555, L563, L579
w/furring channels & 2 layers 1/2" Gypsum Board - L542
w/batt or loose fill insulation - L574
w/resilient channel & batt insulation - L558, L562, L592, M503
Kinetics ICW clip, 2 layers 5/8" Gypsum Board and batt insulation - L581
w/resilient channel & batt insulation & 1 layer 5/8" Gypsum Board - L585
w/1 layer 5/8" gypsum board, resilient channel, & 2 layers 5/8" gypsum board - M500

dwg DWG File

pdf PDF File

fire Precast

2, 3 and 4 Hour - U.L. Design Nos.
J917, J919, J920, J924, J927, J931, J957, J958, J966, J991, J994, K906

dwg DWG File

pdf PDF File

fire Spacejoist TE

1 Hour - No. TSC/FCA 60-01
Without resilient channel, w/ TrusGard® Protective Channel No. FC378

dwg DWG File

pdf PDF File

fire Steel Joist/Metal Decking

1 and 2 Hour - UL Design No. G560 - 16 MSG galv steel joist by Dietrich Industries, Inc.*
1, 1.5, and 2 Hour - G561 - Vulcraft corrugated steel floor and form unites topped with 2 1/2" concrete
1 and 2 Hour - G566 - Gateway Panel Steel Joist, 24" o.c. with 22 MSG corrugated steel deck*
2 Hour - G563 - Marino\Ware Steel Joist, 24" o.c. with 22 MSG corrugated steel deck*
2 Hour - G576 - NUJOIST Steel Joist, 24" o.c. with 16 MSG corrugated steel deck*
2 Hour - G574 - CEMCO Steel Joist, 24" o.c. with 22 MSG corrugated steel deck*

dwg Not Avail.

fire TJL Truss

1 Hour - U.L. Design No. L518 and PFC - 4354

dwg DWG File

pdf PDF File

fire Wood Joist

2 Hour - U.L. Design Nos. L505, L511, L536, L541

dwg DWG File

pdf PDF File

fire Wood Joist

1 Hour - U.L. Design Nos.
Gypsum board screwed direct - L501, L503, L506, L507, L509, L512, L519, L522, L537, L557
Resilient channel - L502, L513, L514, L515, L523, L535
2 Layers gypsum board w/resilient channel - L517
Acoustical ceiling - L004, L206, L525
Suspended Ceiling: L005, L006, L201, L202, L208, L209, L210, L211, L212, L508, L526
w/batt insulation & furring channels - L508
furring channels - L510
w/resilient channel & batt insulation - L516, L533, L545, L593
no insulation, 1 layer Gypsum Board screwed direct - L588

dwg DWG File

pdf PDF File

Wood I Joist

1 Hour - UL Design No. L518, UL Design Nos. L530 w/Simpson Strong-clips;
1-1/2 Hour - UL Design No. L547 TJI®, furring channels without batt insulation;
2 Hour - UL Design No. L538
1 Hour - ITS (Warnock Hersey Test) #J20050694 - Nascor™
1 Hour - ESR-1153 (7 assemblies) 2 layers 1/2" Type X Gypsum Board and Batt Insulation - TJI®
1 Hour - Kinetics Isomax clip, 2 layers 5/8" Gypsum Board and batt insulation - L583
1 Hour - w/ resilient channel and batt insulation and 2 layers 1/2" Gypsum Board - L589

dwg DWG File

pdf PDF File

fire Additional U.L. Design Numbers: (not pictured)

L504 - Prefabricated Floor Panels, 1-hour assembly
L520 - 2x10 Wood Joist 3/4-hour assembly
L539 - 2x10 Wood Joist 1-hour assembly
L540 - 2x10 Wood Joist 1-hour assembly
L543 - Steel Joist 1-hour assembly
L549 - Steel Chord & Web Truss 1-hour assembly
L551 - Steel Chord & Web Truss 1-hour assembly
L552 - Steel Truss 1-hour assembly
L556 - Willamette I Beam Truss 2-hour assembly
L560 - Steel Truss 1-hour assembly
M504 - 2x10 Wood Joist 3/4-hour assembly

dwg Not Avail.

Wall Isolation Detail

Detail Drawing

dwg DWG File

pdf PDF File

Open Beam System

Detail Drawing

dwg Not Avail.

With Radiant Floor Heating and Welded Wire

Detail Drawing

dwg Not Avail.

With Radiant Floor Heating and Plastic Reinforcement

Detail Drawing

dwg Not Avail.

With Crack Suppression Mat (CSM)

Detail Drawing

dwg DWG File

pdf PDF File

Underlayment Depth
Sound Mat Underlayment Depth Underlayment Depth with Maxxon CSM
Acousti-Mat II 1" (25mm) 3/4" (19mm)
Enkasonic 1 1/2" (38mm) 1" (25mm)
Acousti-Mat 3
1 1/2" (38mm) plus Maxxon CSM or wire mesh
1 1/2" (38mm)
Back to Top

Maxxon provides underlayment, Gyp-Crete, gypsum concrete and other flooring underlayment products for new construction, remodeling and renovation.
This site and all contents copyright © 2001-2010 MAXXON Inc. All rights reserved.